Add to Cart
2V 6V 12V Battery Charger Discharger Complete Function Of Data Management Software
1. General
Battery Charger & Discharger HYBT-701 is special equipment for activation of VRLA (hereinafter referred as storage battery) with bad capacity caused by plate sulfuration crystallization. It possesses the functions of “activation” ,“check discharge” and “automatic charging” and etc.
2. Main functions and features
1) Activation function
When the battery is under the conditions of on-line floating charge or off-line, the battery should be activated. Set up activation cycling, charge and discharge time of single activation, protective voltage and other parameters before activation, the instrument would operate activation function automatically; display battery voltage,charge/discharge current,charge/discharge capacity,charge/discharge time and etc at real time; pre-defined activation cycle completion or manually final operation would stop activation process.
2) Check discharge function
Perform check discharge of constant current taking advantage of intellectualized dummy load when the battery is under the condition of off-line, set up the parameters of “discharge current” ,“discharge time” ,“discharge capacity” ,“final voltage”, and the tester could carry out discharge function automatically, display discharge current,battery discharged capacity,the battery voltage, discharge time and etc at real time; when the battery reaches pre-defined final conditions or manually final operation could stop discharge test.
3) Charge function
When the battery is under the conditions of on-line floating charge or off line, operate automatic charge for the battery, set up the parameters of “charge current” ,“charge time” ,“final voltage”and etc, the instrument would operate charge function automatically, and display the data of charge current,battery charged capacity,battery voltage,charge time and etc, when the battery reaches pre-defined final charge condition or manually final operation could stop charge.
4) Real-time data memory
Large data memory. Save 10 groups of activation data,10 groups of check discharge test data,10 groups of charge test data; the user could perform query, deletion and export operation for the data.
5) Data upload and export
The test data could be uploaded to PC by 232 serial port, and could also be exported to U disc for save.
6) Automatic protection function
When detecting battery is abnormal,working of activator is abnormal during test, the activator would stop the test automatically in order to protect the battery.
7)T he activator adopts the design integrating monitoring part with power part
8) Humanized operation interface, simple operation, clear flow, and each operation could have English cue.
9)Sea of blue high-brightness large LCD with clear and nice display effect.
10) Powerful functions of upper computer data management software, friendly interface, which could offer data management, statistics of report forms, automatic creation of test report and etc.
3.Technical data
Measurement type of cell voltage |
2V/6V/12V; |
Measurement range of cell voltage |
2V:0~3V; 6V: 4-8V; 12V:4-15V |
Resolution of cell voltage |
2V: 0.001V,6V: 0.01V, 12V:0.01V |
Voltage testing accuracy |
0.5% |
Working range of charge and discharge current |
2A~100A |
Control accuracy of charge and discharge current |
0.1A |
Current testing accuracy |
1% |
Battery capacity check range |
2V:20-1000Ah; 6V:20-200Ah:12V:20-300Ah; |
Working voltage |
AC 220±15% |
Communication mode |
RS232 communication and USB communication |
Cooling mode |
Refrigeration by blasting |
Working environment |
Temperature: 0℃~40℃ Humidity: 20%~80%RH |
Storage condition |
-20℃~70℃ package and storage |
Display mode |
LCD with High-brightness |
External dimensions(w×h×l) |
450mm×190mm×585mm |
Weight |
11kg |
Carry method |
Portable type ,move with roller wheel |