Wuhan Huaying Electric Power Tech & Science Co., Ltd

Wuhan Huaying Electric Power Tech & Science Co., Ltd 20 YEARS experience in design and manufacture Hipot Test Set Export to 50 Countries Worldwide Professional Technical Support ISO/CE/CNAS/SGS

Manufacturer from China
Active Member
8 Years
Home / Products / CT PT Test Set /

500 VA Field Testing CT PT Test Set Portable With Trolley Case CE Certificated

Contact Now
Wuhan Huaying Electric Power Tech & Science Co., Ltd
City:wuhan
Province/State:hubei
Country/Region:china
Contact Now

500 VA Field Testing CT PT Test Set Portable With Trolley Case CE Certificated

Ask Latest Price
Video Channel
Brand Name :Huaying
Model Number :HYVA-405
Certification :ISO, CE
Place of Origin :Wuhan Hubei China
MOQ :1 Set
Price :Negotiable
Payment Terms :T/T L/C
Supply Ability :50 sets per month
Delivery Time :7 Working Days
Packaging Details :Wooden Case
Power supply :AC220V±10%, 50/60Hz±10%
Voltage output :0.1~180V (AC)
Current output :0.001~5A(RMS)
Power output :500VA
Warranty :1 year free and lifelong maintenance
Customize service :Provided
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

500 VA Field Testing CT PT Test Set Portable With Trolley Case CE Certificated

Equipment Description:

The CT PT test set HYVA-405 is our factory own designed model fully meet the testing requirement of CTs and VTs on site.HYVA-405 has 12.1 inch touch screen for operation and can give test results quickly and intuitively.

Tests for Current Transformer: Tests for Potencial Transformer:
1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement
1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test

Applications of CT/ PT Analyzer:
1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 PT routine test

CT / PT Analyzer can also be used in the following voltage transformer tests:

1) PT turns ratio detection

2) PT polarity check

3) PT secondary winding resistance measurement

4) PT secondary load measurement

Application:

1) CT nameplate parameters check
2) CT parameter check when access to current load
3) analyze the effects of transient characteristics to CT relay protection devices
4) PT nameplate data check
5) PT secondary load check