Wuhan Huaying Electric Power Tech & Science Co., Ltd

Wuhan Huaying Electric Power Tech & Science Co., Ltd 20 YEARS experience in design and manufacture Hipot Test Set Export to 50 Countries Worldwide Professional Technical Support ISO/CE/CNAS/SGS

Manufacturer from China
Active Member
8 Years
Home / Products / CT PT Test Set /

Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight

Contact Now
Wuhan Huaying Electric Power Tech & Science Co., Ltd
City:wuhan
Province/State:hubei
Country/Region:china
Contact Now

Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight

Ask Latest Price
Video Channel
Brand Name :Huaying
Model Number :HYVA-405
Certification :ISO, CE
Place of Origin :Wuhan Hubei China
MOQ :1 Set
Price :Negotiable
Payment Terms :T/T L/C
Supply Ability :50 sets per month
Delivery Time :7 Working Days
Packaging Details :Wooden Case
Power supply :AC220V±10%, 50/60Hz±10%
Voltage output :0.1~180V (AC)
Current output :0.001~5A(RMS)
Power output :500VA
Weight :15Kg
input voltage :AC220V ± 10%, 50Hz / 60Hz ± 10%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight

Equipment Description:

This analyzer HYVA-405 can be called transformers dynamic characteristics tester, voltage and current transformers dynamic characteristics tester, transformer synthesized tester, transformer volt-ampere characteristic tester, CTPT synthesized tester, CT volt-ampere characteristics tester, PT volt-ampere characteristics tester, transformer characteristics synthesized tester, transformer transient characteristics tester, the voltage, ratio change, polarity synthesized tester.

Technical parameters:

1. input voltage: AC220V ± 10%, 50Hz / 60Hz ± 10%
2. output voltage: 0.1 ~ 180V (AC)
3. output current: 0.001 ~ 5A (RMS)
4. output power: 500VA
5. the maximum equivalent inflection voltage: 45KV
6. the current measurement: Range: 0 ~ 10A (autoranging 0.1 / 0.4 / 2 / 10A)
7. the voltage measurement: Range: 0 ~ 200V (autoranging 1/10/70 / 200V)
8. turns ratio measurement: Range: 1 to 35,000,
9. phase measurement: Accuracy: ± 2min, Resolution: 0.01min
10. secondary winding resistance measurement range: Range: 0 ~ 8KΩ (autoranging 2/20 / 80Ω / 800Ω / 8kΩ)
11. Working conditions: Temperature: -10 ℃ ~ 50 ℃, humidity: ≤90%
12. Size: 485mm × 356mm × 183mm
13. Weight: 15Kg

Technical Parameters:

1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2 Power supply: AC220V±10%, 50/60Hz±10%
3 Voltage output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 500VA
6 Maximum knee voltage measurement: 45KV
7 Current measurement:
Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
Error: <±0.1%+0.01%FS
8 Voltage measurement:
Range: 0~200V (automatically change range in 1V/10V/70V/200V)
Error: < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range:1~35000
1~2000 error<0.05%
2000~5000 error<0.1%
5000~35000 error<0.2%
10 Phase measurement: error: ±2min; resolution: 0.01min
11 Winding resistance measurement:
Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error: < 0.2%RDG+0.02%FS
Maximum resolution: 0.1mΩ
12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
13 CT Secondary burden:
Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error: <0.2%RDG+0.02%FS
Maximum resolution: 0.001ohm
14 PT Secondary burden:
Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error :<0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 PT ratio measurement:
Range: 1~35000
1~10000 error<0.1%
10000~35000 error<0.2%
16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17 PT phase angle measurement: maximum error < 3min
18 Make evaluation for test results according to selected standards
19 Make word report for test result
20 Make word reports one time for multi-group test records on the PC
21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22 Compare excitation curves with saved excitation curves in the same window
23 Memory capacity: >1000 groups test results
24 Working condition: temperature: -10℃~50℃; moist: ≤90%

Inquiry Cart 0