Add to Cart
LCD Display Automatic Transformer Testing Equipment With Large Measurement Range
2. Functional characteristics:
1) Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses, capability.
2) Three Methods.
3) Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map.
4) Single machine can do the following 1000KVA distribution transformer full load current experiment; in one third of the rated current, complete 2500KVA distribution transformer load the following test (in one third of the rated current, the instrument can be converted to load loss under rated current parameters, the machine is mainly used in the test bed with integrated supporting the use of transformers.
5) All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results.
6) 320x240 large screen, high brightness LCD display, full English menu and operations to achieve prompt and friendly man-machine dialogue, touch buttons make the operation more convenient, wide LCD with brightness adjustment, can be adapted to the various summer and winter season.
7) Comes with real-time clock, automatically recording test date, time, the preservation of favorable results, management.
8) Panel-type thermal printer which quickly print test results.
9) Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 groups of experimental results with computer on-line data transfer.
10) Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product.
3. Main technical parameters:
Capacity measuring range : 30kVA ~ 31500kVA
Current measurement range:0-100A, auto-switch the measurement range
Current measurement accuracy: ± (0.2% + 3digits)
Voltage measurement range: Line Voltage0-750V;phase voltage 0-450V, auto-switch the measurement range
Voltage measurement accuracy: ± (0.2% + 3digits)
Insulation resistance: > 100MΩ
Leakage current: <3.5mA
Dielectric strength: the power connection on the chassis can withstand: 1500V
External transformer can broaden the scope of measurement instruments;
Frequency Range: 40 ~ 65Hz, accuracy class 0.2;
Power Input: AC220V ± 10%;
4. Panels Description:
1, LCD screen
2, Fuse
3, Earthing terminal
4, Printer
5, Connection terminals to test transformer capacity
6, Connection terminals to test transformer no-load and load loss
7, Power socket
8, Charge switch
9, Power switch;
10, Keyboard