10000V Megger Test Meter Insulation Resistance Test Equipment High Pressure Instrument
Features
1. There are a variety of output voltages HY2303 (2500V, 5000V,10000V), resistance range measuring range up to 0 ~ 400GΩ, resistance measuring range can be automatically converted, and have the corresponding instructions.
2. Insulation resistance simultaneously displayed in two ways: change range of insulation resistance can be easily observed by Analog pointer; Digital Display has measurement accurate results.
3. Embedded and real-time operation of industrial microcomputer software system. High degree of automation, anti-interference ability, equipment can be automatically calculated absorption ratio and the polarization index, without human intervention.
4. User friendly, all measurement results with anti-power-down function, can store 19 consecutive measurements.
5. Produces high-pressure instrument, there are tone output.
6. Built-in residual high voltage discharge circuit, testing is completed on the device under test can be automatically let go of the residual pressure.
7. AC and DC, configuration rechargeable battery and AC adapter.
8. Meter with Portable design for easy field operation.
9. High voltage short circuit current ≥ 1mA, is the measurement of large transformers, transformers, generators, high voltage electric motors, power capacitors, power cables, surge arresters and other ideal insulation resistance test equipment.
Technica table
Output voltage | 2500V DC | 5000V DC | 10000V DC | |
Accuracy | Temperature | 23℃±5℃ | ||
Insulation resistance | 5M~100G ±5% | 10M~200G ±5% | 20M~400G ±5% | |
Other range is ±10% | ||||
Voltage | 2.5M~100G 0~+10% | 5M~200G 0~+10% | 10M~400G 0~+10% | |
Short-circuit Current | ≥1mA | |||
Power source | Adapter Power or charging battery size AA×8pcs Or DC9.6V: charging battery size AA×8pcs
| |||
Operating temperature & humidity range: | -10℃~40℃,Relative humidity 85% or less (no condensation)
| |||
Storage temperature & humidity range: | -20℃~60℃,Relative humidity 90% or less (no condensation)
| |||
Insulation resistance: | 2000MΩMaximum/DC 1000V (Between electrical circuit and enclosure)
| |||
Insulation performance | Can last for 1 minute when the votlage is AC 3KV/50Hz between electric circuit and shell | |||
Size | 230mm×190mm×90mm (L×W×H) | |||
Weight | 2.5kg | |||
Accessory | Test ling package,Power adapter,power cable,instruction manual,charge battery size AA×8pcs |
Panel discription
No. | Name | Function |
(1) | EARTH | Connected to the shell of DUT or on the ground. |
(2) | GUARD | Connected to HV retaining ring of DUT in order to eliminate the effection of surface leakage current.. |
(3) | LINE | High-voltage output terminal, connected to high-voltage conductor of DUT. |
(4) | LCD Display | Display test results and setting parameters |
(5) | SETTING | MEM (Memory):Saving test data or view historical test data, keep pressing more than 3 seconds to delete all the stored datas. Time Setting: Setting Time using the button (Time1,Time2,Time3) Auto off (Backlite):Press the button to light up LCD backlight, and automatically turns off after 90 seconds. Up:Press to forward read data or modify data; Down:Press to back read data or modify data |
(6) | INDICATOR | Showing HV output, power supply working,charging ... |
(7) | TEST KEY | Press Start testing, clockwise rotation can be locked after pressing the button |
(8) | CHARGING JACK | 15-19V DC |
(9) | SHIFT | Selecting Output voltage, also power switch |